Technical data | VVX15 | VVX20 | VVX25 |
Nominal diameter | DN 15 | DN 20 | DN 25 |
Process connection | G¾-ISO 228 male | G1-ISO 228 male | G 1¼-ISO 228 male |
Inner diameter [mm] | Ø 13 | Ø 19 | Ø 25 |
Medium | Water and aqueous solution | ||
Pressure rating | PN 16 | ||
Degree of protection EN 60529 with attached cable socket | IP65 and IP67 | ||
Flow measuring |
|
|
|
Flow measuring range* | 1.5...35 l/min 90...2,100 l/h | 4...80 l/min 240...4,800 l/h | 6.5...150 l/min 390...9,000 l/h |
Accuracy* → at < 50 % of range → at > 50 % of range | ±1 % of range ±2 % of reading | ||
Repeatability | ±1 % at -20...5 °C ambient temperature ±0,5 % at 5...70 °C ambient temperature | ||
Temperature measuring | |||
Measuring range | 0 ... 100 °C | ||
Accuracy | ±1 k | ||
Response time → t50 → t90 |
approx. 1 s approx. 3 s | ||
Temperature ranges |
|
|
|
Medium | -20...90 °C (non-freezing), 100 °C @ max. 80 % Qmax and 60 °C ambient | ||
Ambient | -20...70 °C | ||
Storage | -20...70 °C | ||
Electrical data | |||
Electrical connection | 4- or 5-pin plug connector M12 x 1 | ||
Power supply for output signal → Push Pull or NPN → NPN → 4...20 mA or 0...10 V → IO-Link with Push Pull |
8...30 V DC 5 V DC (±5 %) 12...24 V DC (±10 %) 24 V DC (±10 %) | ||
Current consumption | < 15 mA |
* Test conditions:
→ Test medium water
→ Media temperature 20...30 °C
→ Defined inlet and outlet pipes (see operating manual)
Deviations with media of higher viscosity
Output signals
Four different versions available:
• Frequency output (①)
• Analogue 0.5...3.5 V and frequency output (① + ②)
• Analogue 0...10 V or 4...20 mA and frequency output (① + ③)
• Frequency output with IO-Link (① + ④)
Frequency output ① | VVX15 | VVX20 | VVX25 |
Output signal flow for power supply | Frequency signal, square wave, pulse duty ratio 50:50, signal current max. 20 mA Push Pull or NPN open collector | ||
Pulse rate [1/l] | 500 | 200 | 200 |
Output signal temperature | Pt1000 2 wire, class B or NTC 10.74k, B 0/100 3450 or none |
Analogue output ② | VVX15 | VVX20 | VVX25 |
Output signal flow | 0.5...3.5 V | ||
Scaling [l/min] | 1.5...35 | 4...80 | 6.5...150 |
Voltage rate → 0.5...3.5 V |
0.08955 |
0.03947 |
0.02091 |
Output signal temperature | Voltage signal 0.5...3.5 V corresponds to 0...100 °C or none |
Analogue output ③ | VVX15 | VVX20 | VVX25 |
Output signal flow | 0...10 V or 4...20 mA | ||
Scaling [l/min] | 0...35 | 0...80 | 0...150 |
Voltage rate [V / l/min] → 0...10 V Current rate [mA / l/min] → 4...20 mA |
0.28571 0.45714 | 0.12500 0.20000 | 0.06667
0.10667 |
IO-Link ④ | VVX15 | VVX20 | VVX25 |
IO-Link specification | Version 1.1 | ||
IO-Link Device ID: | 2 | ||
Transmission type | COM2 (38.4 kBaud) | ||
Ready for operation | 2 seconds after supply voltage is applied | ||
Min. cycle time | 103 ms | ||
SIO mode: | Yes | ||
Profiles: | Device Identification, Device Diagnosis | ||
SDCI standard: | IEC 61131-9 | ||
Required master port: | Class A | ||
Process data analog: | 3 | ||
Download IODD device description |
문의 031)243-1035
FAX 031)243-1025
sales@gms-korea.com